Chromatographic Approaches for the Determination of Grapiprant:
A Review
Mansi Shailendra Patil, Sunil Pandit Pawar, Amitkumar Rajkumar Dhankani,
Mansi Amitkumar Dhankani
P.S.G.V.P.M’s College of Pharmacy, Shahada, Maharashtra, India.
*Corresponding Author E-mail: mansipatil6601@gmail.com
ABSTRACT:
Grapiprant (CJ-023423) is a new piprant-class non-steroidal anti-inflammatory medication that reduces pain and inflammation without inhibiting cyclooxygenase (COX) enzymes by specifically antagonising prostaglandin E₂ (PGE₂) EP4 receptors. Compared to traditional NSAIDs, this selective mechanism offers a better safety profile while maintaining protective prostaglandins. Grapiprant has shown encouraging therapeutic promise in both veterinary and human research, and it is mostly recommended for the treatment of osteoarthritis in dogs. The literature claims that a number of analytical techniques for Grapiprant estimation have been documented. As a result, the current evaluation gathers and condenses the published analytical techniques into a single, thorough source. High-Performance Liquid Chromatography (HPLC), Liquid Chromatography–Tandem Mass Spectrometry (LC–MS/MS), spectrofluorimetric techniques, and Reverse Phase-High-Performance Liquid Chromatography (RP-HPLC), including stability-indicating assay methods for method development and validation, have all been used to analyse grapiprant. This review primarily focuses on chromatographic techniques, especially RP-HPLC, which is still the most popular analytical method because of its accuracy, precision, resilience, and suitability for regular quality control examination. We go into great detail about important aspects of method development, such as detection wavelength, flow rate, mobile phase composition, and column selection. Additionally, in compliance with the standards set by the International Council for Harmonisation (ICH) and other regulatory bodies, crucial validation parameters like specificity, linearity, accuracy, precision, robustness, limit of detection (LOD), limit of quantification (LOQ), and system suitability are assessed.
KEYWORDS: Grapiprant, RP-HPLC method, Validation of Method.
INTRODUCTION:
Non-steroidal anti-inflammatory drugs (NSAIDs) are one of the most extensively used classes of medications worldwide due to their vital role in managing inflammation, pain, and fever. An estimated 30 to 50 million people take NSAIDs every day. Beyond their well-known analgesic, antipyretic, and anti-inflammatory qualities, more extensive medicinal uses are being uncovered by continuing study. Even though there are several NSAIDs on the market, efforts are always being made to create new medications that are more selective and have fewer side effects. Even if their mode of action has been thoroughly investigated for years, new compounds are constantly being assessed for their impact on different molecular targets.1
Arachidonic acid is converted into prostaglandin E2 (PGE2), a highly active endogenous mediator, via processes controlled by prostaglandin synthases and cyclooxygenase (COX) enzymes. It binds to four G protein-coupled receptors—EP1, EP2, EP3, and EP4—to produce its biological effects.2 PGE2, one of the body's most widely generated prostanoids, is essential to many physiological and pathological processes. The quest for new therapeutic approaches has accelerated due to the well-documented side effects of standard NSAIDs, such as gastrointestinal toxicity, and selective COX-2 inhibitors, which are linked to cardiovascular risks. Targeting PGE2-mediated pathways specifically, especially by modulating EP receptors, is one intriguing strategy. Because mice lacking EP4 exhibit fewer inflammatory symptoms, research using animal models has shown that the EP4 receptor is essential for inflammatory responses. The importance of the EP4 receptor as a therapeutic target is supported by the notable high amino acid sequence similarity between humans and mice.3
Grapiprant (CJ-023423) belongs to a new class of anti-inflammatory drugs called piprants, which the World Health Organisation formally acknowledged in 2013. Grapiprant blocks the effects of PGE2 without interfering with the synthesis of protective proteinoids because, in contrast to other NSAIDs, it preferentially antagonises the EP4 receptor rather than inhibiting COX enzymes. Grapiprant effectively reduced symptoms over a four-week treatment period, with efficacy comparable to naproxen at conventional doses, according to phase II tests in individuals with osteoarthritis. Its significance in other pathological situations, including colorectal cancer and non-small cell lung cancer, is also being investigated. Grapiprant's extremely specific mechanism of action and favourable safety profile emphasise its promise as a significant advancement in pain and inflammation treatment, even though present research has mostly focused on osteoarthritis, especially in veterinary applications.4
Chromatography:
Chromatography is a method for continuously distributing a component between two phases in order to separate the components of a mixture. One phase (mobile phase) continuously moves over the other phase (stationary phase).
UV spectrophotometry:
The main use of UV spectrophotometric techniques is multicomponent analysis, which reduces the time and expense of the study by minimising the tedious task of removing interferents and enabling the measurement of an increasing number of analytes.5
HPLC (High Performance Liquid Chromatography): High-Pressure Liquid Chromatography, commonly known as High-Performance Liquid Chromatography, is one type of liquid chromatography. It is a popular analytical technique for determining, quantifying, and isolating each constituent of a mixture. HPLC is a more complex type of column liquid chromatography. By compressing the solvent at pressures as high as 400 atmospheres, the HPLC method enables the separation of the sample into distinct constituents according to variations in relative affinities. The solvent is typically propelled through the column by gravity.6
Principle of HPLC:
· During purification, a division column separates the stationary and flexible stages.
· The portable stage is pushed through the partition column under high pressure and can be a dissolvable or dissolvable combination.
· At the end of this operation/run, the HPLC application generates a chromatogram.
· The chromatogram makes it possible to identify and measure the various chemicals.
· As a result, the components of a blend move along the column at different speeds because of the stationary stage's intelligence.
· After exiting the column, specific compounds are identified by an appropriate locator and sent as a flag to the computer's HPLC software.7
Ultra-High Performance Liquid Chromatography (UHPLC):
A more sophisticated and refined variant of HPLC, Ultra-High Performance Liquid Chromatography (UHPLC) is intended to offer quicker, more effective separations with greater resolution and sensitivity. To give thorough data for both qualitative and quantitative examination, the method can be combined with a variety of detectors, such as mass spectrometry (MS) and ultraviolet-visible (UV-Vis) spectrophotometry. Because UHPLC offers faster throughput without sacrificing data quality, it has become the method of choice for regular analysis in pharmaceutical quality control due to its increased efficiency.8
Reverse Phase High Performance Liquid Chromatography (RP-HPLC):
One of the most used chromatography techniques, especially in biochemical and pharmaceutical investigation, is reverse phase high-performance liquid chromatography (RP-HPLC). This method is highly effective for separating complex mixtures of polar and non- polar compounds, including active pharmaceutical ingredients (APIs), impurities, and excipients in drug formulations. RP-HPLC is a vital tool in both research and industry due to its versatility in analysing a broad spectrum of compounds, from small chemical molecules to big macromolecules.9 The goal of this project is to create and verify a reliable analytical technique for grapiprant estimation in pharmaceutical dosage forms and bulk drugs. In order to obtain precise, sensitive, repeatable results that meet regulatory requirements for drug analysis, this study will optimise the methodology.10
Method Validation:
Method validation is an essential prerequisite for drug testing. The validation procedure requires several tests to ensure the analytical testing system is suitable for its intended use and capable of generating precise, reliable analytical results. To accurately assess the failure process, regular configurations, such as additional equipment, should be included in verification. As a result, technical validation analyses vary from product to product.11
1. Specificity: To guarantee that Grapiprant can be precisely identified and measured without interference when contaminants, degradation products, and excipients are present.
2. Linearity: To prove that, within a certain range, the analytical reaction is linearly proportional to the Grapiprant concentration.
3. Accuracy: To verify that the technique yields findings that are reasonably close to the sample's actual Grapiprant value.
4. Precision: To confirm that results are consistent for a brief period of time under the same operating conditions. to assess the method's repeatability under various circumstances, such as different analysts, tools, or days.
5. Limit of Detection (LOD): To ascertain the lowest concentration of Grapiprant that is detectable but not necessarily quantifiable.
6. Limit of Quantitation (LOQ): To identify the lowest quantity of Grapiprant that can be measured quantitatively with a reasonable level of accuracy and precision.
7. Robustness: To evaluate the method's dependability when minor, intentional changes are made to the analytical circumstances.
8. System Suitability: To confirm that, either before or during sample analysis, the analytical apparatus is operating correctly.
9. Range: To determine the range of Grapiprant concentration levels between which the analytical technique exhibits acceptable linearity, accuracy, and precision.
Drug Profile:
· Category: Piprant class NSAID, Selective EP4 receptor antagonist
· Chemical Name: N-([2-[4-(2-ethyl-4,6-dimethyl-1Himidazo[4,5-c]pyridin-1- yl)phenyl]ethyl]aminocarbonyl)-4-[3-(trifluoromethyl)phenyl]benzenesulfonamide
· Molecular Formula: C26H23F3N4O3S
· Molecular weight: 544.54g/mol
· Description: Grapiprant is a selective EP4 receptor blocker used in dogs to reduce pain and inflammation with fewer side effects.
· Melting point: 163–165°C
· Solubility: Freely soluble in Organic solvents like DMSO, methanol. Practically insoluble to very low solubility in water
· Structure:
Figure 1- Chemical Structure of Grapiprant
Mechanism of Action:
Grapiprant works by specifically blocking the prostaglandin E₂ (PGE₂) EP4 receptor, which is the main receptor responsible for osteoarthritis pain, inflammation, vasodilation, and joint swelling. PGE₂ typically activates EP4 and initiates Gs-protein-coupled signalling, which increases cAMP, makes peripheral nociceptors more sensitive, and encourages the release of inflammatory mediators. Grapiprant reduces pain and inflammation without affecting other prostaglandin receptors by selectively antagonistically blocking this receptor. In contrast to conventional NSAIDs, which block COX-1 and COX-2 and reduce all prostaglandins, including those that shield the kidneys, stomach, and platelets, grapiprant maintains these protective properties. Its improved safety profile, particularly in older animals with comorbidities or with prolonged usage, is explained by this focused mechanism, which also effectively relieves joint pain, stiffness, and movement-related discomfort.
Reported Methods for Grapiprant:
1. In 2018, A new method of liquid chromatography-tandem mass spectrometry (LC-MS/MS) quantifying the CJ-023423 (grapiprant, an EP4 receptor antagonist) in rabbit plasma was developed and validated by Elena Baralla et al. The LC–MS/MS was sensitive, selective, accurate and precise enough to perform pharmacokinetic studies. For this purpose, a LUNA C18 column (100 × 2.1mm, 5µm), equipped with a C18 security guard cartridge as a stationary phase, was used for chromatographic separation. 0.2% formic acid in water (A) and 0.2% formic acid in acetonitrile (B), each at a flow rate of 0.2mL/min, were applied as mobile phase with gradients. Tandem mass spectrometry with electrospray ionisation in positive mode (ESI+) operating in multiple reaction monitoring (MRM) was used for detection. Grapiprant's retention time of 2.6 minutes demonstrated quick and effective separation. Over the concentration range of 5–1000ng/mL, calibration curves were linear. The limits of quantitation (LOQ) and detection (LOD) were 5ng/mL and 1.5 ng/mL, respectively.
Table 1: Optimized LC-MS/MS Conditions for Grapiprant
|
Parameter |
Description |
|
Column Name |
LUNA C18 (100 × 2.1 mm, 5 µm) |
|
Mobile Phase |
0.2% Formic acid in water (A): 0.2% Formic acid in acetonitrile (B) (Gradient mode) |
|
Flow Rate |
0.2 mL/min |
|
Detection |
LC–MS/MS (ESI+, MRM mode) |
|
Retention Time |
2.6 min |
|
Linear Range |
5–1000 ng/mL |
|
LOD |
1.5 ng/mL |
|
LOQ |
5 ng/mL |
2. In 2015, A high-performance liquid chromatographic technique with spectrofluorimetric detection was created and verified in 2015 by Virgina De Vito and associates to quantify CJ-023423 (grapiprant) in canine plasma. For pharmacokinetic applications, the HPLC-FL method showed good sensitivity, selectivity, accuracy, and precision. A Synergi Polar-RP 80A analytical column (150mm × 4.6mm, 4µm) was used as the stationary phase for chromatographic separation. The mobile phase was supplied in isocratic mode at a flow rate of 1 mL/min and comprised acetonitrile and 20mM ammonium acetate buffer (pH 4.0) at a ratio of 70:30 (v/v). A fluorescence detector with an excitation wavelength of 320nm and an emission wavelength of 365 nm was used for detection. Grapiprant showed satisfactory separation without interference with a retention time of 9.75±0.23 minutes. With LOD and LLOQ of 3ng/mL and 10ng/mL, respectively, calibration curves were linear in the 10–500ng/mL range.
Table 2: Optimized HPLC-FL Conditions for Grapiprant
|
Parameter |
Description |
|
Column Name |
Synergi Polar-RP 80A (150mm × 4.6mm, 4 µm) |
|
Mobile Phase |
Acetonitrile: 20mM Ammonium acetate (pH 4.0) (70:30 v/v) |
|
Flow Rate |
1mL/min |
|
Detection |
Fluorescence detection (Ex: 320 nm, Em: 365nm) |
|
Retention Time |
9.75 min |
|
Linear Range |
10–500ng/mL |
|
LOD |
3ng/mL |
|
LLOQ |
10ng/mL |
3. In 2013, to facilitate pharmacokinetic research, Yuji Yamaoka and associates developed and validated a liquid chromatography–tandem mass spectrometry (LC–MS/MS) technique for the measurement of grapiprant (CJ-023423) in dog plasma. High sensitivity, selectivity, accuracy, and precision were demonstrated using the LC–MS/MS technique. An Inertsil ODS-3 C18 column (50mm × 2.1mm, 5µm) was used as the stationary phase to accomplish chromatographic separation. Acetonitrile and 0.1% formic acid (70:30, v/v) in water supplied at a flow rate of 0.2mL/min made up the mobile phase. Tandem mass spectrometry with electrospray ionisation in positive ion mode was used for detection. Grapiprant's retention time was roughly 2.1minutes, demonstrating quick and effective separation. The approach is appropriate for pharmacokinetic evaluation because the calibration curve was linear over the concentration range of 5–5000ng/mL.
Table 3: Optimized LC-MS/MS Conditions for Grapiprant
|
Parameter |
Description |
|
Column Name |
Inertsil ODS-3 C18 (50mm × 2.1mm, 5µm) |
|
Mobile Phase |
Acetonitrile: 0.1% Formic acid in water (70:30 v/v) |
|
Flow Rate |
0.2mL/min |
|
Detection |
LC–MS/MS (ESI positive mode) |
|
Retention Time |
~2.1min |
|
Linear Range |
5–5000ng/mL |
4. In 2022, A stability-indicating reverse-phase high-performance liquid chromatography (RP-HPLC) method for quantifying Grapiprant in bulk and pharmaceutical dose forms was developed and validated by Khalid M. Al-Shaalan and associates. Excellent sensitivity, accuracy, precision, and resilience were shown by the RP-HPLC method, which makes it appropriate for regular quality control and stability investigations. A Zorbax Eclipse XDB-C18 column (150mm × 4.6mm, 5 µm) was used as the stationary phase for chromatographic separation. Acetonitrile and 0.1% orthophosphoric acid in water (60:40 v/v) were administered in isocratic mode at a flow rate of 1.0 mL/min as the mobile phase. A UV detector with a wavelength of 254nm was used for detection. Grapiprant's retention time of roughly 5.32 minutes showed good separation from degradation products. Over the concentration range of 5–60µg/mL, the calibration curve was linear, demonstrating the method's appropriateness for quantitative analysis.
Table 4: Optimized RP-HPLC Conditions for Grapiprant
|
Parameter |
Description |
|
Column Name |
Zorbax Eclipse XDB-C18 (150mm × 4.6mm, 5µm) |
|
Mobile Phase |
Acetonitrile: 0.1% Orthophosphoric acid (60:40v/v) |
|
Flow Rate |
1.0mL/min |
|
Detection Wavelength |
254nm |
|
Retention Time |
5.32 min |
|
Linear Range |
5–60 µg/mL |
5. In 2022, A reverse phase high-performance liquid chromatography (RP-HPLC) method for estimating grapiprant in pharmaceutical dose form was created and verified by Sushma Rani and associates. Good accuracy, precision, specificity, and robustness were shown by the devised RP-HPLC method, making it appropriate for routine quality control analysis. An Inertsil ODS C18 column (250mm × 4.6mm, 5µm) was used as the stationary phase to accomplish chromatographic separation. The mobile phase was supplied in isocratic mode at a flow rate of 1.0mL/min and contained acetonitrile and phosphate buffer (pH 4.8) at a ratio of 65:35 (v/v). A UV detector with a wavelength of 260nm was used for detection. Grapiprant was shown to have an effective separation time of 4.85 minutes. The method's suitability for quantitative estimation was confirmed by its linearity over the concentration range of 10–60 µg/mL.
Table 5: Optimized RP-HPLC Conditions for Grapiprant
|
Parameter |
Description |
|
Column Name |
Inertsil ODS C18 (250mm × 4.6mm, 5 µm) |
|
Mobile Phase |
Acetonitrile: Phosphate buffer (pH 4.8) (65:35 v/v) |
|
Flow Rate |
1.0mL/min |
|
Detection Wavelength |
260nm |
|
Retention Time |
4.85min |
|
Linear Range |
10–60µg/mL |
CONCLUSION:
The documented analytical techniques for measuring
Grapiprant in pharmaceutical and biological matrices are compiled and assessed
in this review. For routine quality control, RP-HPLC is the most popular
technology because of its accuracy, precision, and robustness. For assay and
pharmacokinetic research, additional techniques such as UV-spectrophotometry
and LC-MS/MS have also been investigated.
All things considered, this review offers a comprehensive resource for
academics and analysts looking for trustworthy analytical methods for
Grapiprant estimation and validation.
ACKNOWLEDGEMENT:
The author(s) would like to express sincere gratitude to their institution for providing the necessary facilities and support to carry out this work.
REFERENCES:
1. Al-Saeed A. Gastroenterological and cardiovascular risk of nonsteroidal anti-inflammatory drugs. Oman Medical Journal. 2011; 26: 385-391.
2. Chen Y, Bedson J, Hayward RA, Jordan KP. Trends in prescribing of non-steroidal anti-inflammatory drugs in patients with cardiovascular disease: Influence of national guidelines in UK primary care. Family Practice. 2018; 35:426-432.
3. Sugimoto Y, Narumiya S. Prostaglandin E receptors. Journal of Biological Chemistry. 2007; 282:11613-11617.
4. Legler DF, Bruckner M, Uetz-von Allmen E, Krause P. Prostaglandin E2 at a new glance: Novel insights in functional diversity offer therapeutic chances. International Journal of Biochemistry and Cell Biology. 2010; 42:198-201.
5. Saldanha TC, de Araújo MU, Neto BB, Chame HC. Simultaneous analysis of Co˛⁺, Cu˛⁺, Mn˛⁺, Ni˛⁺ and Zn˛⁺ in the ultraviolet region using 4-(pyridyl-2-azo) resorcinol and multivariate calibration. Analytical Letters. 2000; 33(6): 1187-1202.
6. Thammana M. Review of high-performance liquid chromatography (HPLC). Research and Reviews: Journal of Pharmaceutical Analysis. 2016; 5(2): 22-28.
7. Thammana M. Review of high-performance liquid chromatography (HPLC). Research and Reviews: Journal of Pharmaceutical Analysis. 2016; 5(2): 22-28.
8. Ahmed F, et al. Principles and applications of ultra-high-performance liquid chromatography. In: High-Performance Liquid Chromatography – Recent Advances and Applications. IntechOpen; 2023. doi:10.5772/intechopen.110540.
9. Soares JX, Santos Á, Fernandes C, Pinto MMM. Liquid chromatography on the different methods for the determination of lipophilicity: An essential analytical tool in medicinal chemistry. Chemosensors. 2022; 10(8): 340. doi:10.3390/chemosensors10080340.
10. Sagar PM, Mankar SD, Dig SB. An overview of analytical method development and validation in bulk and pharmaceutical dosage forms. Asian Journal of Pharmaceutical Analysis. 2023; 13(3): 222-228.
11. Unacademy. HPLC: Definition, principle, parts, types and uses. NTA-UGC Study Material–Pharmaceutical Analysis. Unacademy; 2023.
|
Received on 02.05.2026 Revised on 11.06.2026 Accepted on 13.07.2026 Published on 12.10.2026 Available online from October 21, 2026 Asian Journal of Pharmaceutical Analysis. 2026; 16(4):302-306. DOI: 10.52711/2231-5675.2026.00046 ©Asian Pharma Press All Right Reserved
|
|
|
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License. Creative Commons License. |
|